You are in: Instruments > NIFS > Performance and Use > Sensitivity     

[NIFS]

NIFS Sensitivity Estimates

NIFS detector-related information (relevant to the following analysis) is summarized below

The NIFS Integration Time Calculator (ITC) is not fully functioning yet. Therefore, for System Verification proposals the on-sky performance of NIFS should be estimated based on the commissioning data. During the commissioning run, we observed a faint UKIRT standard star (FS111). Measured peak count per pixel values for FS111 with the four NIFS filters are:

Band Magnitude
(FS 111)
Peak signal
in 85 sec
(ADU/pixel)
Peak count in 1200 sec
ADU / pixel e- / pixel
Z 10.60 977 13,793 38,620
J 10.65 1241 17,520 49,056
H 10.43 4173 58,913 164,956
K 10.28 3672 51,840 145,152

Relevant noise sources (all e- /pixel) for one 1200 sec exposure and estimated source brightness for 5 sigma detection limits are:
Band Noise components Approx. Magnitude for total S/N ~ 5 in the peak for 1200s exposures
ReadNoise
(e-/pixel)
Dark current
(e-/pixel)
Bg. continuum
(e-/pixel)
Total noise in 1200s exp.
(e-/pixel)
Mag. mJy
Z 7.3 17 3 22.8 17.0 -
J 7.3 17 4 22.8 17.2 0.21
H 7.3 17 20 24.5 18.3 0.05
K 7.3 17 168 35.0 17.6 0.06

Note that the S/N calculation in the above table includes the Poisson noise from the target object - the S/N ~5 is for all noise sources: readnoise + dark noise + background noise + Poisson noise from object.

Once the NIFS integration time calculator gets fixed, then this page will be updated. The updated page will have information for extended sources as well like in other Gemini instruments' sensitivity estimate pages.

[Science Operations home] [NIRI home]


Last update 2005 Nov 25; Tracy Beck & Inseok Song