You are in: Instruments > T-ReCS > Performance and Use > T-ReCS Components > Detector    

T-ReCS Detector

Manufacturer Raytheon SBRC
Design Impurity-band Conductor (IBC)
Multiplexer CRC-774
Format 320×240 pixels
Pixel Size 50 µm
# Outputs 16
Well Depth Switchable:
Low Background ~ 3e6 e-
High Background ~ 1e7 e-
Active Layer Si:As
Wavelength range 5–28 µm (QE ~ 40% at 10 microns)

 

On the sky the T-ReCS pixel size is 0.0896 arc-seconds with an uncertainty of about 0.0003 arc-seconds (3 sigma). The instrument alignment angle is checked at intervals using a suitable double star. It was 358.1 degrees from the middle of 2003 until April 28 2004 when it was changed to 357.8 degrees to adjust for a small mis-alignment. The default orientation has the short axis of the array oriented north-south, such that T-ReCS images have north up and east at left to a precision of order 0.3 degrees at worst. The precision depends on how recently the alignment has been checked and whether the cassegrain rotator has been re-initialized since the last adjustment.

 

[Science Operations home] [T-ReCS home]


Last update 2004 Jun 16; Kevin Volk
In original form; Tom Hayward