As of August 2006, non-Michelle-specific information on mid-IR observing, calibration and data reduction (such as baseline calibrations, standard star information and overheads) can be found on the general MIR home page.


Status and availability: Michelle is available for classical and queue-scheduled imaging and spectroscopic use. See the current Call for Proposals for further details and the associated instrument calendar for target RA constraints.
Modes of operation: Michelle has several modes of operation. These are summarised on the Michelle Introduction page.
Michelle Components: See the Michelle components page for details of filters, gratings, slits, detector and other components.
Sensitivity: The Integration Time Calculator can provide estimates of required integration times for the available observing modes. Tables of sensitivities based on measurements at the telescope are available. Be sure to use an on source time of 0.5 for imaging and low resolution spectroscopy and 1.0 for medium and high resolution spectroscopy (see below) .

The estimated image quality delivered to the instrument is given as part of the observing condition constraints.

Chopping, Nodding, and Guiding:
As with other mid-IR imagers and spectrographs, accurate cancellation of the sky and telescope background present in imaging and low resolution spectroscopic modes is most readily achieved by the techniques of chopping and nodding. When observing with the medium resolution gratings and the echelle, nodding only (without chopping) may be used, similar to the conventional 1-5 um technique.

Currently the maximum chopper throw allowed on Gemini is 15 arcsec, which is considerably smaller than the Michelle field of view. Also, guiding with a peripheral wavefront sensor is presently performed on one side of the chop only, so the quality of the two chopped images will differ significantly and the value of the two unguided images will be marginal except under exceptional circumstances. Two basic chop/nod methods are available:

  1. Beam-switching, in which the nod is parallel to and the same amplitude as the chop. If the chop is sufficiently small and the target is also small this will result in a final frame containing three separate images of the target, the central one being guided and the other two unguided, with the central image having been obtained in half of the integration time.
  2. Perpendicular nodding, in which the nod is perpendicular to and a similar amplitude as the chop. For a small chop and nod this would result in four images of the target on the frame, two guided and two unguided, with each image corresponding to one-fourth of the integration time.
The default chop/nod method is beam-switching. PI's must specifically request perpendicular nodding if they want it. See the telescope characteristics for more details of the chopping performance.
Observing overheads:
Mid-IR observing overheads can be significant and must be taken into account when proposing for time on Michelle. Please see this discussion of Michelle overheads and efficiency.
Calibration:

Mid-IR calibrations are discussed in detail on the general mid-IR web pages. A baseline calibration set will be taken for each observation. Only one star or asteroid will be observed, so if the observer requires more than one star or asteroid, time for the additional measurements will come out of the science allocation and should be allowed for in the initial time request.

Wavelength calibration is derived from the telluric absorption lines in the calibration spectrum.

Observing strategies:
See the mid-IR observing strategies page for guidance and special considerations for each observing mode. When writing your proposal, don't forget to review the proposal checklist. Successful applicants should check the instructions for setting up Michelle observations in the observing tool.

Data processing and software: The Gemini IRAF MIDIR package has been released. These scripts allow basic data reduction for imaging and spectroscopy - see the MIR home page for more details. For imaging polarimetry further reduction with polarimetry software outside of IRAF, such as the Polpack package in the Starlink software, is likely to be needed. IRAF does not provide a polarimetry package, so complete polarimetry reductions are not possible in the Gemini/MIDIR package.

Target acquisition:
Involves visual observation and recognition (using the Gemini Acquisition Camera) or infrared acquisition using Michelle's imaging mode. See also the mid-IR astrometry page.