|
Michelle Performance and Use |
As of August
2006, non-Michelle-specific information on mid-IR observing,
calibration and data reduction (such as baseline calibrations,
standard star information and overheads) can be found on the general MIR home page.
| Status and availability: |
Michelle is available for classical and queue-scheduled imaging and
spectroscopic use. See the current Call for
Proposals for further details and the associated instrument
calendar for target RA constraints.
|
| Modes of operation: | Michelle has several modes of
operation. These are summarised on the Michelle Introduction page.
|
| Michelle Components: | See the
Michelle components page for details of filters, gratings, slits,
detector and other components.
|
| Sensitivity: | The Integration Time
Calculator can provide estimates of required integration
times for the available observing modes. Tables of sensitivities based on
measurements at the telescope are available. Be sure to use an on
source time of 0.5 for imaging and low resolution spectroscopy and 1.0
for medium and high resolution spectroscopy (see below) .
The estimated image quality delivered to the instrument is
given as part of the observing
condition constraints.
|
| Chopping, Nodding, and Guiding: |
As with other mid-IR imagers and spectrographs,
accurate cancellation of the sky and telescope background present in
imaging and low resolution spectroscopic modes is most readily
achieved by the techniques of chopping and
nodding. When observing with the medium resolution gratings and
the echelle, nodding only (without chopping) may be used, similar to
the conventional 1-5 um technique.
Currently the maximum chopper throw allowed on Gemini is 15 arcsec, which is considerably smaller than the Michelle field of view. Also, guiding with a peripheral wavefront sensor is presently performed on one side of the chop only, so the quality of the two chopped images will differ significantly and the value of the two unguided images will be marginal except under exceptional circumstances. Two basic chop/nod methods are available:
|
| Observing overheads: |
Mid-IR observing overheads can be significant and must be taken into account when proposing for time on Michelle. Please see this discussion of Michelle overheads and efficiency. |
| Calibration: |
Mid-IR calibrations are discussed in detail on the general mid-IR web pages. A baseline calibration set will be taken for each observation. Only one star or asteroid will be observed, so if the observer requires more than one star or asteroid, time for the additional measurements will come out of the science allocation and should be allowed for in the initial time request. Wavelength calibration is derived from the telluric absorption lines in the calibration spectrum. |
| Observing strategies: |
See the mid-IR observing
strategies page for guidance and special considerations for each
observing mode. When writing your proposal, don't forget to review the
proposal checklist. Successful
applicants should check the instructions for setting up
Michelle observations in the observing tool.
|
| Data processing and software: | The Gemini IRAF MIDIR package has
been released. These scripts allow basic data reduction for imaging
and spectroscopy - see the MIR
home page for more details. For imaging polarimetry further
reduction with polarimetry software outside of IRAF, such as the Polpack
package in the Starlink software,
is likely to be needed. IRAF does not provide a polarimetry package,
so complete polarimetry reductions are not possible in the
Gemini/MIDIR package. |
| Target acquisition: |
Involves visual observation and recognition (using
the Gemini Acquisition Camera) or infrared acquisition using
Michelle's imaging mode. See also the mid-IR astrometry page.
|
Last update 21 Feb 2006; K. Volk, R. S. Fisher & T. R. Geballe