Hokupa'a-85 Sensitivity

Sensitivity estimates for Hokupa'a-85 on Gemini South are provided here.

For reference, the following table lists the magnitude zero points (for 1 ADU/s) and the sky brightnesses. For J, H, and K the zero-points were measured from data taken during the ??  run. 

Hokupa'a+ABU Zero-points and Sky Brightnesses
Filter Magnitude Zero Pt. Sky Background (mag/arcsec2) Sky Background (ADU/s/pix) Notes
J 25.3 15.4 4+-2 a
H 25.6 13.9 20+-5 a
K 24.9 12.0 60+-20 a

Notes to table:
(a) Zero points were measured from data taken during the ?? run.

Point Source Sensitivities:

The limiting magnitudes for point sources were calculated for a 5-sigma detection for the flux within the 50% encircled energy diameter in a one hour integration (total on-source exposure time). Median seeing conditions and an on-axis bright guide star (R < 15 mag) were assumed. Magnitude zero points in J, H, and K were taken from the table above. Please use these sensitivities for S/N calculations.

The sensitivity limits depend on the performance of the adaptive optics system. In particular under poorer performance conditions (e.g. operating in worse seeing or for when using an off-axis guide star), the limiting magnitude will be brighter. For example, in 0.85'' seeing the larger 50%EED diameter results in a limiting magnitude about 1 magnitude brighter.

(5 sigma, 1 hour, pt. source within 50% EEDb) Hokupa'a+QUIRC Point Source Sensitivities
Filter 50% EED (arcsec) limiting flux density (Magnitude) limiting flux density (microJy) Notes
J 0.30 23.9 0.4 a
H 0.24 23.1 0.6 a
K 0.18 22.1 1.0 a

Notes to table:
(a) PSFs were simulated and matched (for K-band) to dedication images. The residual jitter and the aberrations in QUIRC were inferred (no high-order telescope aberrations are assumed). The table assumes a seeing of r0 = 23cm (0.5'' seeing). The magnitude zero points were measured from the ?? run.
(b) Using a 100 mas aperture improves the sensitivity in H and K by about 0.2 magnitudes.

Extended Source Sensitivities:

The limiting magnitudes for extended sources were calculated for a 5-sigma detection for the flux within one square arcsecond in a one hour integration (total on-source exposure time). Magnitude zero points in J, H, and K were taken from the table above.

Note that the source is assumed to be isolated (e.g. not near a bright star). In cases where there is a bright star nearby, the limiting magnitude will be strongly affected by the distribution of light in the point spread function.

(5 sigma, 1 hour, ext. source within 1 sq. arcsec) Hokupa'a+QUIRC Extended Source Sensitivities
Filter limiting flux density (mag/sq. arcsec) limiting flux density (microJy/sq. arcsec) Notes
J 22.8 1.2 a
H 20.7 6.0 a
K' 18.7 22 a

Notes to table:
(a) The magnitude zero points were measured from the ?? run.

[Science Operations home] [Hokupaa home]


Last update July 21, 2004; Bob Blum