Hokupa'a-85 Components


H85 CAD DWG

Hokupa'a-85 (H85) mounted on the Gemni South ISS port 4 (silver box). The drawing shows the four major subassemblies of H85 and the science camera, ABU (1-5 um imager, green frame and red vacuum vessel). The central purple box is the H85 optical bench. The turquoise box holds the APD racks. The associated electronics and computers are located in the thermal electronics enclosure (purple box), and the instrument frame (blue) holds everything to the ISS.


Optical components of the Science Path in H85. Light (f/16) from the telescope enters from the left and is collimated at the off-axis paraboloid 1 (oap1). A pupil image of the Gemini secondary is formed at the 85 element deformable mirror (DM). This mirror is also mounted on a tip-tilt (TT) stage. Light is passed through the bench to the WFS side at folds 2 & 3. The "sci fold" is in fact on the other side of the bench and refers to the final downward reflection which sends the science beam (now f/32) to the ABU instrument. An auxiliary science filter wheel is located before the scifold on the bench for warm filters.


Light entering the WFS side of the H85 bench hits the beam splitter (BS). Light short ward of 1 um is sent to the WFS and long ward to the science camera ABU. After passing thru a collimator, the field steering mirror (FSM), picks of the 4'' field which contains the WFS guide star. This light is sent thru the "P60" mirror which makes an f/60 beam and directs it to the membrane mirror...


...which produces the alternate intra and extra focal images which are re-imaged on the WFS lenslet array (LLA). The LLA feeds the avalanche photodiodes (APDs) by means of a fiber bundle.

[Science Operations home] [Hokupaa home]



Last update 20 July; Bob Blum