The Gemini MCAO
|
MCAO by itself can not produce data. It stabilizes the beam and restore the diffraction limit of the telescope. Therefore it has to come with a suite of instrument, designed along requirements which are derived from the study of the science case (cf MCAO Workshop). Efficient utilization of the MCAO system will depend upon the availibility of a large field IRMOS and a near-IR imager with complimentary design characteristics. Both instruments should be matched to the F/32 output beam of the MCAO system, and provide diffraction-limited image quality over the field of view. Such instruments would yield unique scientific capabilities before the launch of NGST sometimes around 2010. The IRMOS would remain competitive with NGST given sufficient spectral resolution.
Wavelength |
1 - 2.5 microns |
Field |
80'' x 80'' (4k x 4k) |
Sampling |
0.02'' |
In addition, the following is desired:
Wavelength |
1 - 2.5 microns |
Field per IFU |
3 - 5'' |
Spatial sampling |
0.1'' |
Spectral resolution (2 pixels) |
5000-10000 |
Patrol Field |
circular, 2' diameter |
Comments: